GE 531X304IBDAMG1 contact input group Isolation terminal board
Brand ABB Color Standard Application Industrial height 370mm rated current 476mA
Protection Level IP45 Suitable for motor power 108KW Application Site Power Industry BOM Number GJR2391500R1220 Power industry HIEE401782R0001 Part number 531X304IBDAMG1
Applicable pipe 2 Whether imported is weighing 5.69 kg can be sold nationwide

GE 531X304IBDAMG1 contact input group Isolation terminal board
The 531X304IBDAMG1 is a contact input group isolation terminal board developed by GE. The 24 dry contact inputs are connected to two palisade terminal blocks on the isolated contact input (TBCI) terminal board. For contact excitation, TBCI is coupled to a DC power supply. A noise reduction circuit in the contact input protects against surges and high frequency noise.
TBCI supports simplex and TMR applications and works with VTCC/VCRC. The TBCI is connected to the VME rack, where the VCCC or VCRC processor board is placed via a cable with a molded plug. Both the TBCIH B and TBCIH C variants of the board are suitable for Mark VI and function identically. The nominal voltage is 24 V dc.
531X304IBDAMG1 installation
wiring
Connect the 24 dry contact input cables directly to the two I/O terminals on the terminal board. Two screws hold the blocks in place, and they can be unplugged from the board for maintenance. Each block has 24 terminals and can hold up to #12 AWG of wire. On the left side of each junction box is a shielded junction panel connected to the grounding of the case.
Power connection
Connect the TBCI to the contact excitation voltage source using plugs JE1 and JE2.
Wiring connection
The connector JR1 is used in a simplex system to connect TBCI to the I/O processor. Use connectors JR1, JS1, and JT1 to connect TBCI to the I/O processor in the TMR system. Depending on the type of Mark VI, Mark VIe, or Mark VIeS system and the level of redundancy, insert the cable or I/O packet.
531X304IBDAMG1 operation
At each input near the signal input point, the filter reduces high-frequency noise and controls surges. The dry contact input on the H1 is powered by a floating 125 V DC (100-145 V DC) power supply controlled by the turbine. The 125 V DC bus is subject to current limitation in the distribution module before power is supplied to each contact input. As shown in the specification sheet, the H2 and H3 variants use lower voltages.
diagnosis.
Perform the following diagnostic tests on the components on the patch board:
Measure the excitation voltage. If the excitation falls below 40% of the nominal voltage, the I/O component/board sets and locks a diagnostic warning.
As a test, all panel inputs are set to the disconnected contact (fail-safe) state. Any input that does not pass the diagnostic test is forced into fail-safe mode, resulting in a failure.
If the input from that board does not match the TMR voting values from all three boards, a fault is issued.
Each terminal board connector has its own ID device, which is queried by the I/O packet/board.

GE 531X304IBDAMG1 contact input group Isolation terminal board
GE IS200SPROH1AAB MRP663860
GE IS210BPPBH2CAA
GE RS-FS-9001
GE SR489-P5-HI-A20-E
GE VMIACC-5595-208 350-805595-208J
GE GESSBS-6AH256
KOLLMORGEN AKM33E-ANCNR-00
GE IC698RMX016-ED
GE IC698CRE030-DE
GE IC687BEM731-AB
GE IC698CHS009A
GE IC698PSD300C
GE IC698PSA350E
GE RXE2N0Q0J132A
GE IC695CPU320
GE 369-HI-R-M-F-E-H-E
GE DS3820PSCB1C1B
GE 04240FD11234A
GE IC695CPU320-CF
GE VMIVME-5565-110000
GE IC693TCM302
GE 04220FL11232A
GE IC752SPL013-BA EX2100
GE V7668A-1310B0 350-9310007668-131020 D
GE PMC422-LAM D2
GE V7668A-131000 350-9310007668-131000 B
GE V7668A-1310B0 350-9310007668-131020 B
GE H201Ti122
GE VMIVME-3122
GE VMIVME-2540
GE VME-PMC-CADDY