ABB CI858-1 Module (ABB S800 Communication Card)
Brand ABB color Standard Application Industrial height 586mm rated current 186mA
Protection level IP45 Suitable for motor power 86KW Application Site Power Industry BOM Number GJR2391500R1220 Power industry HIEE401782R0001 Part Number CI858-1
Applicable pipe 2 Whether imported is weighing 5.88 kg can be sold nationwide

ABB CI858-1 Module (ABB S800 Communication Card)
All kinds of signal transmission lines connected with the PLC controller control system, in addition to the effective transmission of all kinds of information, there will always be external interference signal intrusion.
There are two main ways of this interference: one is through the transmitter power supply or the power supply of the shared signal instrument into the grid interference, which is often ignored; Second, the signal line is interfered by electromagnetic radiation induction in space, that is, the external induction interference on the signal line, which is very serious. The interference introduced by the signal will cause the abnormal work of the I/O signal and the measurement accuracy will be greatly reduced, and the components will be damaged in serious cases. For the system with poor isolation performance, the signals will interfere with each other, causing the bus backflow of the common ground system, resulting in logical data changes, misoperation and crash. PLC controller control system due to signal interference caused by I/O module damage is quite serious, resulting in a lot of system failures. Grounding is one of the effective means to improve electromagnetic compatibility (EMC) of electronic equipment. The correct grounding can not only affect the electromagnetic interference, but also the equipment can send out interference; The wrong grounding will introduce serious interference signals, so that the PLC system will not work normally. The ground wire of the PLC controller control system includes the system ground, ground, alternating ground and protection ground. The disturbance of the grounding system to the PLC controller system is mainly the uneven distribution of potential at each ground point, and the ground potential difference between different ground points, which causes the ground loop current and affects the normal operation of the system. For example, the cable layer must be grounded at one point. If A and B at both ends of the cable layer are grounded, there is a ground potential difference, and a current flows through the layer. When an abnormal state occurs, such as lightning strikes, the ground current will be larger.

ABB CI858-1 Module (ABB S800 Communication Card)
ABB 3HAC5518-1
ABB 3HAC5566-1
ABB 3HAC6157-1
ABB 3HAC6428-1/04
ABB 3HAC7344-1
ABB 3HAC7681-1
ABB 3HAC9710-1
ABB 5360673-01
ABB 57160001-KX
ABB 5SDD1060F0001
ABB 5SDF0860H0003
ABB 5SGY3545L0003
ABB 5SGY3545L0017
ABB 5SHX06F6004
ABB 5SHX1060H0003
ABB 5SHX10H6004
ABB 5SHX14H4502
ABB 5SHY3545L0003
ABB 5SHY3545L0005
ABB 5SHY35L4510
ABB 5SHY35L4520
ABB AI845
ABB AI880-1
ABB AO845A
ABB AO845A-eA
ABB ARC093AV1
ABB ARCOL 0338
ABB ARCOL 0339









