ABB 07KT97F1 automation control system CPU module

ABB 07KT97F1 automation control system CPU module

ABB 07KT97F1 automation control system CPU module

Brand ABB color Standard Application Industrial height 325mm rated current 460mA
Protection Level IP45 Suitable for motor power 126KW Application Site Power Industry Material Code GJR2391500R1220 Power industry HIEE401782R0001 Part No. 07KT97F1
Applicable pipe 2 Whether imported is weighing 5.18 kg can be sold nationwide

ABB 07KT97F1 automation control system CPU module

Brand ABB color Standard Application Industrial height 325mm rated current 460mA
Protection Level IP45 Suitable for motor power 126KW Application Site Power Industry Material Code GJR2391500R1220 Power industry HIEE401782R0001 Part No. 07KT97F1
Applicable pipe 2 Whether imported is weighing 5.18 kg can be sold nationwide

ABB 07KT97F1 automation control system CPU module

PROFIBUS DP Network configuration In order to realize the communication and control between DCS and ABB frequency converter and M102, the first step is to complete the network configuration of PROFIBUS in DCS. The configuration is mainly designed from the following four aspects. (1) Network design: mainly from the communication rate, from the number of stations, redundancy security. Because the frequency converter and M102 communication rate is different, and in order to prevent the interference of the frequency converter, we placed the frequency converter and M102 in different network segments; The devices that are mutually alternate in the process flow are placed in different network segments. (2) Hardware connection: Connect each frequency converter or M102 to the PROFIBUS interface module (master station module) in the corresponding PKS system according to the design. The master station module uses FLASH-ROM to store network configuration, and supports automatic reconfiguration of the slave station device after power recovery. (3) Install GSD file: Each PROFIBUS communication device has a GSD file provided by the manufacturer, and the corresponding GSD file needs to be installed before configuration. The GSD files of the frequency converter and M102 are ABB_0812.GSD and INTC08DD.gsd respectively. (4) Configuration: the master station and slave station in DCS are added to the network. Set the network address of the master station and the slave station, select the correct module for each slave station, and configure the main parameters. 2.1 Configuration of M102 According to the requirements of the process, the electrical devices that are alternate to each other are connected to two different PROFIBUS networks (two PBims form two independent networks) through the SST PROFIBUS configuration tool. After adding the M102 GSD file, you can see M102_Motor_Control in the corresponding slave library.

ABB 07KT97F1 automation control system CPU module

ABB DI610
ABB DI620
ABB DI810
ABB DI814
ABB DLM01
ABB DO610
ABB DO630
ABB DPW01
ABB DRA02
ABB DSAI146
ABB DSAO110
ABB DSBB175
ABB DSDP170
ABB DSDX404
ABB DSIH72VP ENOK
ABB DSPC170
ABB DSPC172
ABB DSPC172H
ABB DSPC406
ABB DSQC202
ABB DSQC313
ABB DSQC322
ABB DSQC327A
ABB DSQC346G

 

Scroll to Top