3BHE009681R0101 3BHB012961R0001 5SHX2645L0002 Module

3BHE009681R0101 3BHB012961R0001 5SHX2645L0002 Module

3BHE009681R0101 3BHB012961R0001 5SHX2645L0002 Module

Brand ABB Color Standard Application Industrial height 145mm rated current 319mA
Protection level IP45 Suitable for motor power 326KW Application Site Power Industry Material Code GJR2391500R1220 Power industry HIEE401782R0001 Part No. 3BDH000741R1 CTI21-P Ex
Applicable pipe 2 Whether imported is weighing 4.18 kg can be sold nationwide

3BHE009681R0101 3BHB012961R0001 5SHX2645L0002 Module

Brand ABB Color Standard Application Industrial height 145mm rated current 319mA
Protection level IP45 Suitable for motor power 326KW Application Site Power Industry Material Code GJR2391500R1220 Power industry HIEE401782R0001 Part No. 3BDH000741R1 CTI21-P Ex
Applicable pipe 2 Whether imported is weighing 4.18 kg can be sold nationwide

3BHE009681R0101 3BHB012961R0001 5SHX2645L0002 Module

For adequate ventilation. Consider the heat generated by other devices in the enclosure. For PV1000 terminals, the ambient temperature around the terminals must be 0… 55°C(32… 131°F). Provides access to the terminal backplane for wiring, maintenance, memory card installation, and troubleshooting. Tools in addition to the tools required for making panel cuts, other tools required for installation are: • Small flat-head screwdriver • Torque wrench (N•m, lb•in) with a flat-head or crossheave driver Mounting dimensions The following figure shows the mounting dimensions of the PanelView 1000 grayscale and color terminals. CI858K01 3BSE018135R1 LDGRB-01 3BSE013177R1 CI854AK01 3BSE030220R1 APBU-44C 64669982 NDCU-33CX 3AUA0000052751 5SHY3545L0014 CI854AK01 3BSE030220R1 PPD113B01-10-150000 3BHE023784R0123 PFSK151 3BSE018876R1 PM864AK01 3BSE018161R1 PFSK152 3BSE018877R1 PFSK151 3BSE018876R1 PFSK165 3BSE027778R1 VP74201-933CW07 UFC760BE141 3BHE004573R0141 PFSA140 3BSE006503R1 PM825 3BSE010796R1 SB522V1 3BSC760015R1 REF543KM129AAAB 3BHE006373R0101 XV C769 AE101 PanelView The 1000 touch terminal uses the panel notch that comes with the terminal to cut an opening in the panel. Remove any sharp edges or burrs. 2. Ensure that the terminal sealing gasket is correctly positioned on the terminal, as shown in the following figure. The washer forms a compression seal. Do not use sealants.

3. Although the keyboard legend plugin can be installed at any time, we recommend that you install it after installing the terminal. 4. Insert the terminal into the cut on the panel. 5. Install 6 mounting clips (2 at the top, 2 at the bottom, and 1 on each side); The end of the clip slides into the slot on the terminal. Hand tighten the clamp mounting screw until the washer seal evenly touches the mounting surface
1. Secure the holder base to the existing memory card slot using the two screws provided. Tighten the screw to 0.7… 0.9 N•m(6… 8 lb•in) of torque. 2. Insert the memory card and install the holder until it is properly inserted. 3. To remove the retainer, press the lug on both sides and pull.

Connect the L1 version (directory number 2711-T10G1L1) of the PV1000 terminal to the 24V DC power supply. The electrical ratings of PanelView 1000 terminals are as follows. Electronic circuits and internal fuses protect terminals from reverse polarity and overvoltage conditions. Resetting the terminal will reinitialize the PanelView terminal (same as the cyclic power supply). Follow these steps to reset the PV300, PV300 Micro, PV550(keyboard, keypad, and touch screen), or PV600(keyboard, keyboard, and touchpad) terminal. • Simultaneously press the left arrow, right arrow,,

Then type ↵ key. The terminal performs its power-on sequence. The order of the keystrokes (when running the application) determines what appears after the reset. • If you press the left arrow key and the right arrow key ↵ key before typing, the Configuration Mode menu is displayed. • If you press the arrow key before the Enter key ↵, the terminal runs the loaded application. Follow these steps to reset the PV550 and PV600(touch only)/PV900/PV1000/PV1400 terminals. 1. Press the reset button using a narrow, non-conductive tool. The terminal performs its power-on sequence.

Configuring Terminal Chapter Objective This chapter describes how to use the Configuration Mode menu to configure terminal Settings and perform operations, including how to: • Access the Configuration Mode menu. • Choose a language. • Use a memory card. • Configure communication (DH485, DH+, Remote I/O, ControlNet, DeviceNet, DF1, EtherNet/IP). • Configure presets. • View terminal information. • Set the time and date. • Adjust the display parameters. • Set up the printer. Application Settings Configuration parameters are set from the terminal or from the PanelBuilder32 software when the application is created. If the following options are enabled in the Terminal Settings dialog box of the PanelBuilder32 software, the Settings downloaded with the application take precedence over the terminal Settings. In addition, the application may allow the controller to change the following while the application is running: • Time and date • Current display • Boot control list

3BHE009681R0101 3BHB012961R0001 5SHX2645L0002 Module

ABB SC513
ABB SE96920414 YPK112A
ABB SNAT617CHC
ABB SPA-ZC22
ABB SPAD346C
ABB SPCJ4D34-AA
ABB TA524
ABB TB521-ETH
ABB TC625
ABB TC630
ABB TET106 11355-0-6050000
ABB TK516
ABB TU515
ABB TU804-1
ABB TU810V1
ABB XI16E1
ABB XM06B5
ABB XO16N1-B20 XO16N1-C3.0
ABB YB560100-EA S3
ABB YYT107A
ABB 07KT97H3
ABB 086329-003
ABB 086329-004
ABB 086345-504
ABB 086351-004
ABB 12KM02E-V0002
ABB 3BHB003154R0101

Scroll to Top