Sc-510-5-2300-s0 AC servo controller

Sc-510-5-2300-s0 AC servo controller

Sc-510-5-2300-s0 AC servo controller

Brand ABB Color Standard Application Industrial height 349mm rated current 232mA
Protection Level IP45 Suitable for motor power 336KW Application Site Power Industry Material Code GJR2391500R1220 Power industry HIEE401782R0001 Part No. SC510
Applicable pipe 2 Whether imported is weighing 4.88 kg can be sold nationwide

Sc-510-5-2300-s0 AC servo controller

Brand ABB Color Standard Application Industrial height 349mm rated current 232mA
Protection Level IP45 Suitable for motor power 336KW Application Site Power Industry Material Code GJR2391500R1220 Power industry HIEE401782R0001 Part No. SC510
Applicable pipe 2 Whether imported is weighing 4.88 kg can be sold nationwide

Sc-510-5-2300-s0 AC servo controller

Master station control bus data transmission. When the master station has bus access (token), no external request is required to transfer data. Passive device. That is, the slave stations, etc., do not have any bus access: they only inform the recipient of a message or respond to a request from the master station. The baud rate is supported from 9.6k to 12M and the maximum number of devices is 126. Data exchange

The main station and the slave station are mainly circulatory. The necessary communication functions are detailed in the basic functions of PROFIBUS-DP and comply with the EN50170 standard. Each master has full access to read and write its own slave, but can only read the slave that accesses the other master. Data cannot be exchanged directly between the master station and the slave station. Non-periodic services such as parameter tuning and diagnosis can also be performed between the master station and the slave station (DP-V1). These can be synchronized as the main station circulates data.

AC500 structure

1. Backlit LCD display and operation buttons

2. SD card slot

3. Plug-in extension communication module (from 1, 2 to up to 4 communication processors)

4. Integrated communication interface on CPU baseboard (Ethernet or ARCNET)

5. FBP bus adapter (FieldBusPlug-FBP) (PLC can only be used as slave station)

6. Two serial ports, for programming, ASCIl communication, Modbus communication or CS31 communication (PLC can only be used as the main station)

7. A maximum of 10 local I/0 expansion module baseboards can be installed

Sc-510-5-2300-s0 AC servo controller

ABB DAO01
ABB DDI01
ABB DDO01
ABB DLM02
ABB DSAI133A
ABB DSDO115A
ABB DSDX453
ABB DSPC454
ABB DSQC332A
ABB DSQC504
ABB DSQC509
ABB DSQC633
ABB DSRF197K01
ABB DTCC901B
ABB DTDX991A
ABB FPX86-9329–C
ABB GCC960C102
ABB GCC960C103
ABB GDC801B101
ABB HAC319AEV1
ABB ICSI16E1
ABB IMASI23
ABB IMBLK01
ABB IMDS014
ABB IMDSI14
ABB IMDSM04
ABB IMFECI2
ABB INIIT03
ABB INIIT13
ABB INIT03